8 Mechanical components
8.1

Included mounting material

Included

components

Cable gland +

Lock nut


closing glad

Motor

PTC

Mounting

clamps

Centring

bit

M M M M M M M M

12 16 20 25 40 12 16 50

Cable diameter

[mm]

3,7 - 7

4,5 - 10

7 - 13

9 - 17

15 - 23

2.015 – 2.022

2 (3)

2

2

3 1 1

4

1

4.022 – 4.040

2 (3)

2

2 3 1 1

4

1

4.055 – 4.110

2 (3)

2 2 3 1

1

4

1

4.150 – 4.185

4 (5)

2

2

4

2

1

1

4

1

4.220

4

(5)

2 2 4 2 1 1

4

1

( ) max. available cable entries

8.2

Optional components

8.2.1 Mounting accessories

Mounting ring

Available for diameters:

140 mm

155

mm


CAUTION!

If the HYDROVAR is mounted on a
motor with a plastic fan cover, a
stainless-steel mounting ring must be
used to support the weight of the
HYDROVAR.

8.2.2 Sensors

• pressure-transducer

• temperature-sensor

• differential-pressure-transducer

• flow indicator

• level-sensor

(

orifice plate, inductive flow meter)

8.2.3 Filter

• Line-coils

8.2.4 Cable entry (only HV4.150 – 4.220)

• Multiple cable entry (M50)

8.2.5 Ready-made motor cables

Available for HV 2.015 – 4.220