Xylem HYDROVAR HV 4.150 / 4.185 / 4.220 User Manual

Page 39

Advertising
background image


39


*

Terminals X3/5 and 6

can be used as actual value voltage input and also as digital input. Also the voltage signal input on

terminal X3/15 can be used as digital input.

**

X3/3 and X3/24 Æ ∑ max. 100mA

Additional power supply

** max. 100 mA


Current signal input (required val. 2)

0-20mA / 4-20mA [Ri=50Ω]

To determine the required value or the offset

Analogue output 2

4-20mA

Analogue output 1

0-10 VDC




Current signal input (required val. 1)

0-20mA / 4-20mA [Ri=50Ω]

To determine the required value or the offset


Voltage signal input (required value 2)

0-10 VDC

*DIG 4

To determine the required value or the offset

Voltage signal input (required value 1)

0-10 VDC

To determine the required value or the offset

Low water

e.g. incoming pressure switch or water level switch required


Configurable digital input 1

DIG 1

e.g. for switching between 2 required values or sensors


External ON/OFF (release)

Actual-value-voltage input sensor 1

0-10 VDC

*DIG 2

Actual-value-voltage input sensor 2

0-10 VDC

*DIG 3

Actual-value-current input sensor 2

0-20mA / 4-20mA [Ri=50Ω]

Sensor supply

** max. 100 mA

Actual-value-current input sensor 1

0-20mA / 4-20mA [Ri=50Ω]

Ground