Before You Begin – Read This

CAUTION

Leaking underground storage tanks ( USTs ) and fuel lines cause serious

environmental and health hazards. The Tank Sentinel

®

system is designed to detect leaks

in tanks by tank tightness / leak testing with liquid level probes, and/or with leak detection
sensors. You must follow the instructions in this manual carefully to ensure that the
system is programmed properly and is effective in detecting leaks.

– Site Information Required

• Site Plan? — showing the location, size, and model #s of all tanks, probes and sensors
• Dispenser Manufacturer Documentation?
• Pump Manufacturer Documentation? — Type, Model #s, and suction inlet

distance off

the bottom

of each tank (to determine the lowest product level and highest water level)

• Pump Control Required ? — enable / disable pumping... TS-IEM Output modules (for

TS-2001/508 consoles only), or a TS-ROM1 BriteBox

• Remote Device Control Required? — use TS-IEM (see above), or a TS-ROM2 BriteBox
• Remote Tank Overfill Alarm / Acknowledge Installed ? — (TS-RA1 or TS-RA2 / TS-RK)

Type, Model, Size and Manufacturer of each Tank

• Tank Manufacturers’ Tank Chart / Strapping Table (s)? — for each tank or the diameter

and length of each tank

• Are any tanks identical ? — (tanks, probe data, and alarm limits can be copied)
• Standard Probe Data? — (model number, shaft length, gradient, serial number)
• Special Probe Data? — (ie RTD / Temperature sensor locations)
• Tank # & Probe # — model number assignments and input channels for each tank
• Leak Detection Sensors? — installed in or near or associated with each tank including

input channel number assignments

• Product? — in each tank (API specific gravity) and the type & number of float(s) / probe
• State and Local Regulations? — (testing requirements, reporting requirements, and

hotline numbers, and other information that you and/or the customer will need)

– Other Sources of Information

Use the TOC (Table of Contents) to find information within this manual and see the

following INCON documentation:
• Installation Guide

• Operator’s Guide

• TroubleShooting Guide

• Leak Detection Sensor – Installation Guides (one per type / family of sensor)
• Tech Service Bulletins

• Application Bulletins

• Application Notes