Explanaton – Yokogawa DAQWORX User Manual

Page 96

Advertising
background image

2-66

IM WX103-01E

Explanaton

Run Dsplay

See the explanation in section 2.11, “Pausing/Resuming the Updating of the Monitor Display
and Reading Measured Values Using Cursors” for further information on “Record Information.”

• Man Status

Displays the main operating status of the MXLOGGER.

Communication error

: Connected, : Disconnected

Current time

Displays the data rate using a bar

Move the cursor here to display

the data rate in bytes/second

Monitor/Record status

: Stopped, : Monitoring (green), : Recording (red)

Write error

: No, : Yes

Data dropout

: No, : Yes

• Dsk Informaton

Used disk space

Displays the amount of used disk space using a bar

Move the cursor here to display the remaining space

as a percentage

Free disk space

• Unt Status

Displays the status of each unit.

(yellow): Broken module

(red): Module different from

the configuration

! (yellow): Calibration error module

Data dropout

: No, : Yes

Monitor/Record status

: Stopped, : Monitoring (green), : Recording (red)

Status and

Capacity of the CF card

Communication error

: Connected, : Disconnected

: Inserted,

: Not inserted,

: Inserted but not available

: Free space *.* MB

: Used space (orange)

• Status dsplay bar at the bottom secton of the Man wndow

Current

time/record time

Monitor/Record status

: Stopped

: Monitoring

: Recording

Show the Monitor Server window

Displayed only when the monitor server

is running (See 2.14, “Setting Up the

Monitor Server”)

Show the DDE server window

Displayed only when the DDE server is

running (See 2.15, “Setting Up the DDE Server”)

Display-Alarm ACK button

Displayed only when an alarm is occurring (see page 2-64)

Click here to acknowledge alarms

Icon indicating the writing is in progress

Displays the icon and the number of remaining data files to be written

Error indication while writing

To acknowledge, click the respective button

: Write error ACK button

: Data dropout ACK button

Communication status

: Connected, : Disconnected

Display when events are executing

Displayed only when events are being

executed (see 2.9, “Event Processing”)

Note

If there are data files that have not been finalized (data writing have not been completed) in the
previous connection, the finalization of the data file is carried out immediately when the Logger
is started. If this happens, the remaining number of data files that have not been finalized is
shown to the left of the icon indicating that the writing is in progress on the status display bar
at the bottom section of the Main window. The remaining number indicates the progress of
finalization. If the remaining number is zero, it is not displayed.

2.10 Startng/Stoppng Data Montorng and Dsplayng the Montor

Advertising