If Power Failure Occurs While Report Function Is Active

The DR recorder takes different actions depending on the length of a power failure.
If the power failure time is longer than 12 hours:

The DR recorder makes a report immediately after it recovers from the power failure and then
stops making reports. It does not execute printing based on the settings for automatic printing.
Print out reports either using the communication function or from the FUNC menu.
Results of computing: The DR recorder computes data measured up to the point immediately

before the power failure.

Time of report making:The time when the power failure occurred.

If the power failure is less than 12 hours:

The DR recorder takes different actions depending on the time it recovers from the power
failure.

Time of Recovery from

After the Time of

Before the Time of

Power Failure

Report Making

Report Making

Condition after recovery from

Valid report function

Valid report function

power failure

(start of report making enabled)

(start of report making enabled)

Report making

Immediately after recovery from

Time for report making

power failure

Report printing

Immediately after recovery from

Time for report making

power failure

Data included in report making

Data measured up to the point of

Data measured over the given

power failure

period except the power failure time

If automatic report printing is turned on:
If the power failure time covers the given period of report making, no report for that period is made.

Handling of Faulty Data

If data being computed contain any faulty data, the DR recorder treats the data as summarized in
the following table, depending on the type of computing and faulty data.

Type of Faulty Data Average

Minimum/Maximum

Instantaneous Value

Sum

Positive overflow

Excluded from

Included in computing

Takes faulty data as

Excluded from

computing

the result of computing

computing

Negative overflow

Excluded from

Included in computing

Takes faulty data as

Excluded from

computing

the result of computing

computing

Channels included in

Excluded from

Excluded from computing Takes faulty data as

Excluded from

measurement set to SKIP

computing

the result of computing

computing

No channel included

Excluded from

Excluded from computing Takes faulty data as

Excluded from

in measurement

computing

the result of computing

computing

Error

Excluded from

Excluded from computing Takes faulty data as

Excluded from

computing

the result of computing

computing

Output of data disabled

Excluded from

Excluded from computing Takes faulty data as

Excluded from

computing

the result of computing

computing

The DR recorder prints the results of computing as shown in the following table if they are special
data.

Type of Data

Printout Format

Positive overflow

+******

Negative overflow

–******

Channels included in measurement set to SKIP

Space

No channel included in measurement

Space

Error

ЧЧЧЧЧЧ

Output of data disabled

If data being computed contain faulty data, the DR recorder prints each digital data item,
beginning with an * or × as the status indication.
1. Power failure:

×

In the case of a power failure, the DR recorder prints the time for report making, also beginning
with an

×.

2. Channels included in measurement set to SKIP/no channel included in measurement/error/

output of disabled data:

×

10.12 Working with the Report Function