8 alarm module, Alarm module -26 – Yokogawa DR240 User Manual

Page 271

Advertising
background image

14-26

IM DR232-01E

14.8 Alarm Module

Style Number: S2
Type, Number of outputs, Contact mode, Terminal type

Contact mode

Transfer contact (NO-C-NC)

Make contact(NO-C)

Terminal type

screw

screw

Number of

output

4

10

Type

DT200-11

DT200-21

Normal operating temperature/humidity

20 to 80%RH for 0 to 40

°C, 10 to 50%RH for 40 to 50°C (no condensation)

Output updating rate

every measurement interval

Contact mode

Make contact

: normal open/common contact type

Transfer contact: normal open/common/normal close type

Energize/de-energize

switchable

Hold/non-hold

switchable

Reflash alarm

up to 6 contacts can be specified.

Contact capacity

250V DC/0.1A (with a resistor load)
250V AC/2A (with a resistor load)
30V DC/2A (with a resistor load)

Dielectric strength

Between the output terminal and ground: 2300V AC (50/60Hz) for one minute.

Power consumption

Included in the main unit or the subunit to which the module is to be installed.

External dimensions and weight

Weight (kg)

0.3
0.4

External dimensions(W)

×

(H)

×

(D)mm

apporox. 57

Ч137Ч68

apporox. 57

Ч137Ч68

Type

DT200-11
DT200-21

Advertising
This manual is related to the following products: