4 error codes, Error codes -4 – Yokogawa DR240 User Manual

Page 237

Advertising
background image

13-4

IM DR232-01E

13.4

Error Codes

If servicing is necessary, or if the recorder does not operate correctly even though the following
corrective actions have been taken, contact your nearest Sales representative. Addresses may be
found on the back cover of this manual.

Error Code

Error

Corrective Action

001

System error.

Contact your nearest representaive.

002

Set data out of range.

Set numeric data correctly.

003

Time set incorrectly.

Set time correctly.

004

Channels set incorrectly.

Set channels correctly.

005

Invalid setting function parameter.

Set parameter correctly.

006

Invalid character string.

Set character string correctly.

007

Invalid type of input for input module.

Set the type of input correctly.

008

Invalid range setting for input module.

Set range correctly.

009

Numeric values out of range.

Set numeric values correctly.

011

Attempted to do manual, header, list or

Install new chart paper.

setup list printout at the end of chart paper.

030

There may be a module that cannot be set

Re-set ranges or channels with

in channels with continuous ranges.

continuous ranges.

031

There may be an invalid module in channels

Change channels in which

with continuous ranges.

continuous ranges are set.

040

Reference channel number greater than

Change the reference channel number.

that of the channel for interchannel
differential computations.

041

Skipped range in the reference channel for

Change the range in the reference channel.

interchannel differential computations.

042

RPJC range in the reference channel for

Change the range in the reference channel.

interchannel differential computations.

043

SCALE in range setting in the reference

Change the range in the reference channel.

channel for interchannel differential
computations.

044

The reference channel for interchannel

Change the reference channel number.

differential computations does not exist.

045

The left and right spans are identical.

Change the scale setpoint.

046

The left and right scale values are identical.

Change the scale setpoint value.

060

The alarm setting was made in the channel

Change ranges.

where SKIP was set.

061

The alarm was set to a channel with ranges

Change ranges.

where alarm setting cannot be set.

062

The alarm setpoint is out of range in a

Set correct alarm setpoint.

channel with continuous ranges.

063

Relay number set incorrectly.

Set relay number correctly.

080

Invalid character strings for group setting.

Set character strings correctly.

081

Invalid channel in character string for group

Set channel correctly.

setting.

083

Partial compaction set to a channel where

Change ranges.

SKIP was set.

084

Partial compaction set to a channel in

Change ranges.

which ranges cannot be partially compacted.

085

Partial compaction out of range in a channel

Set correct partial compaction range.

with continuous ranges.

086

The left and right zones have the same values. Change zone set values.

087

The left zone is wider than the right zone.

Change zone set values.

088

The left and right zones are less than 5 mm

Change zone set values.

apart wide.

089

Copy channel setting error.

Sets the correct channel.

090

Attempted to copy a message with the same

Change copy source or destination.

source and destination number.

091

Illegal protocol for logic setting.

Set correct protocol.

100

No equation option

Not possible to make any computation

settings.

101

Invalid code in the equation

Set the equation correctly.

102

Incorrect number of ( ) in the equation

Set the correct number of ( ).

103

Syntax error

Set the equation correctly.