Yokogawa DR240 User Manual

Page 247

Advertising
background image

14-2

IM DR232-01E

14.1 Specifications of DR232/DR242 and DS400/DS600

Logging mode

purple

Recording accuracy

Dot recording:

±(0.1% of recording span + measurement accuracy)

Max. recording resolution

Dot recording:

±0.1mm

Recording interval

Dot recording interval for analog trend recording:

FIX:Min. 2s, and same as measurement interval (skipped recording in case of 0.5/1s scans)
AUTO:Min. 2s and linked to measurement interval and chart speed

Digital printout interval for analog trend recording:

MULTIPLE: Specify for each channel from 6 kinds of intervals
SINGLE : Determined automatically from the chart speed and the number of channels used

to print digital values.

Digital value printing interval in the logging mode:

MULTIPLE:Specify for each channel from 6 kinds of intervals
SINGLE:Common to all points
Recording interval change: 2 kinds; changes by event/action function

Recording modes

Analog trend mode and logging mode

Chart paper feed

Chart speed:1 to 1500 mm/hour
Chart speed change:2 kinds; changes by event/action function
Chart feed method:by pulse motor
Chart feed accuracy:

±0.1% of length (when recording is performed continuously for at least

1000mm; does not include elongation or shrinkage of paper)

Recording start/stop

Usually starting and stopping of recording is done by means of key operation. However, this can
also be done by the event/action function.
Normal recording
Trend recording on alarm occurrence: trigger/level
Group trend recording

Auxiliary printing functions

During analog trend recording and logging, setting information and comments and such will be
printed. Chart speed (mm/hour)

× analog trend recording interval must not exceed 3000.

Printout items:

Engineering unit, channel number/TAG, alarm, scale, title, message

Event/Action function

Recording can be started, or the chart speed changed by alarm output status/remote control signal/
chart end signal/timer or key operation.

Relation between the chart speed and recording interval (analog trend mode)

however, chart speed (mm/hour)

× analog trend recording interval must not exceed 3000.

Chanel No.

TAG

Alarm scale

message

Digital print

Record disabled

Record enabled

Record enabled

Record enabled

1~9mm/h

10~1500mm/h

Chart speed

Record enabled

Record enabled

Recording interval for digital printout and chart speed

When the logging interval is SINGLE:
however, chart speed (mm/hour)

× analog trend recording interval must not exceed 3000.

24

8

4

2

10~24mm/h

25~49mm/h

50~99mm/h

100~1500mm/h

Chart speed

Number of digital print rows

1 row

12

4

2

1

2 row

8

4

2

1

3 row

6

2

1

1

4 row

Unit : hour

When the logging interval is MULTIPLE:
Set by timer.