14-7

IM DR232-01E

Specifications

14

Information on and Process in Case of Power Failure

• The DR recorder adds ¥ to the time on a printout provided upon recovery from a power failure.

It does not print the character, however, if it has been more than 12 hours since the power
failure occurred.

• The DR recorder excludes data occurring during a power failure from its reports.
• If the DR recorder recovers from a power failure after the time to make a report, it makes a

report immediately after the recovery.

• In an application where the REPORT PRINT menu item is set to on for automatic printing, the

DR recorder prints a report only immediately after it recovers from a power failure if the power
failure time is less than 12 hours and the recorder has recovered after the preset time for report
printing.

• In an application where the REPORT PRINT menu item is set to on for automatic printing, the

DR recorder prints a report at the scheduled time for report printing if a power failure time is
less than 12 hours and the recorder has recovered before the preset time for report printing.

• If a power failure time is longer than 12 hours, the DR recorder stops report making even if the

power is restored.
The recorder prints a report (for data acquired up to the power failure), however, immediately
after it recovers from the power failure.

• If a power failure time is longer than 12 hours, the DR recorder does not print a report even if

the menu item for automatic printing is set to on. In that case, you can print a report from the
FUNC menu or send data to a communication output.

Time Intervals for Printing

Type of Report

Printing Format

Number of Columns

Chart Length

Printing Time

Hourly report

Standard

77

20 cm

approximately 4 minutes

Daily report

Standard

77

20 cm

approximately 4 minutes

Enhanced

437

114 cm

approximately 22 minutes

Monthly report

Standard

77

20 cm

approximately 4 minutes

Enhanced

542

141 cm

approximately 27 minutes

The printing time is maximum when you print an hourly report and a daily report each in the
standard format and a monthly report in the enhanced format, all at the same time.

Required printing time: 4 + 4 + 27 = 35 (minutes)

Format of Output via Communication

Binary

14.1 Specifications of DR232/DR242 and DS400/DS600