Show environment power – Avaya C460 User Manual

Page 164

Advertising
background image

Chapter 2 Avaya C460 CLI Commands

152

Avaya C460 Reference Guide

show environment power

User level: read-only, read-write, admin.
Use the show environment power command to display the current power
configuration for the switch, the total power available to the system, and amount of
power currently in use.
L The “Main Power” includes two supervisor modules and the fan module,

irrespective of the number of supervisor modules installed.

L The “Main Draw” column shows the demand for an I/O module whether its

slot is enabled or not.

The syntax for this command is:

show environment power

Example:

Total working fans

• 9
• 8
• less than 8

Fans not installed

• No fan tray installed

C460 > show environment power

PSUs Configuration Admin: redundancy

PSUs Configuration State: no redundancy (2 active PSU(s))

Power Available Drawn Remaining

----- --------- ----- ---------

Main 411W 411W 0W

PoE 1589W 0W 1489W

Slot

Module Type

Active Enabled

Priority

Main

Draw

PoE

Budget

PoE

Draw

Fault

----

---------------

------ -------

-------- ----

------

----

-----

1 M460ML-SPV

Y

Y

critical

68W

2 M460ML-SPV

Y

Y

critical

68W

3 M4612ML-G

Y

Y

low

59W

4 M4648ML-T-2G-PWR

Y

Y

high

48W

720W

100W

5 M4648ML-T-PWR

Y

Y

low

48W

720W

0W

6 M4648ML-T-2G

Y

Y

low

70W

* Fans power consumption: 45(W)