Sync spv, Tech, Sync spv tech – Avaya C460 User Manual

Page 236

Advertising
background image

Chapter 2 Avaya C460 CLI Commands

224

Avaya C460 Reference Guide

sync spv

User level: read-write, admin.
Use the sync spv command to synchronize the following between an Active
Supervisor Module and Halted Supervisor Module:

Boot bank

Firmware images

Device manager image

L You can only execute this command from the active Supervisor Module CLI.

The syntax for this command is:

sync spv

The synchronization may take up to 90 seconds to complete.

Example:

L The configuration is synchronized after you perform a reset.

tech

Use the tech command to enter tech mode. This command is reserved for service
personnel use only.

C460-1(super)# sync spv

This command may overwrite the neighbor SPV software and

reset it

*** Confirmation *** - do you want to continue (Y/N)? y

Copying Bank A to the neighbor SPV ...

Copying Bank A to the neighbor SPV done

Copying Bank B to the neighbor SPV ...

Copying Bank B to the neighbor SPV done

Copying Embedded Web image to the neighbor SPV ...

Copying Embedded Web image to the neighbor SPV done

Setting boot bank of the neighbor SPV ...

Setting boot bank of the neighbor SPV done

Setting chassis sync on for the neighbor SPV...

Setting chassis sync on for the neighbor SPV done

SPVs are resetting.

Please wait till the process is finished. The SPVs will be

synchronized after the reset is completed

Advertising