2 electrical installation, 1 network topology, Electrical installation – Lenze E84DGFCR User Manual

Page 22: Network topology, Communication manual 8400 motec profinet, Sd d d, Cs s s

Advertising
background image

Communication manual 8400 motec PROFINET

Installation

Electrical installation

22

L

EDS84DMOTPNET EN 2.0 - 11/2011

5.2

Electrical installation

5.2.1

Network topology

It is typical of PROFINET to have a rather free topology the limiting factor of which is large

message latencies due to e.g. switches connected in series.



Internal switch latency

( 19)

The combination of a line and a stub is useful for system wiring.
PROFINET supports the following topologies:

 Switch / star

[5-2]

Switch / star topology (S = switch, D = I/O device)

 Tree via switches

[5-3]

Tree topology (C =I/O controller, S = switch)

"Inverter Drives 8400 motec" hardware manual
Here you will find detailed information about ...
• the digital and analog inputs/outputs;
• the relay output;
• the integrated safety system (safety option);
• the wiring of the connections.
Observe the notes and wiring instructions included.

E94YCER005

S

D

D

D

E94YCER006

C

S

S

S