4 error information (error), Error information (error), Communication manual 8400 motec profinet – Lenze E84DGFCR User Manual

Page 59: Parameter data transfer error information (error)

Advertising
background image

EDS84DMOTPNET EN 2.0 - 11/2011

L

59

Communication manual 8400 motec PROFINET

Parameter data transfer

Error information (error)

9.4

Error information (error)

Error code

Meaning

Description

Additional

information

0x0000

Impermissible parameter

number

Access to non-available parameter

-

0x0001

Parameter value cannot be

changed

Change access to a parameter value that cannot be

changed

Subindex

0x0002

Lower or upper value limit

exceeded

Change access with value beyond the value limits

Subindex

0x0003

Faulty subindex

Access to non-available subindex

Subindex

0x0004

No array

Access with subindex to non-indicated parameter

-

0x0005

Wrong data type

Change access with value that does not go with the

data type of the parameter

-

0x0006

No setting permitted (only

resettable)

Change access with a non-zero value, where it is not

permitted.

Subindex

0x0007

Description element cannot

be changed

Change access to a description element that cannot

be changed

Subindex

0x0008

Reserved

(PROFIdrive profile V2: PPO-Write requested in IR is

not available)

-

0x0009

Description data is not

available

Access to non-available description (parameter value

is available)

-

0x000A

Reserved

(PROFIdrive profile V2: Wrong access group)

-

0x000B

No parameter change rights Change access if the parameter change rights are

missing

-

0x000C

Reserved

(PROFIdrive profile V2: Password is wrong)

-

0x000D

Reserved

(PROFIdrive profile V2: Text in the cyclic traffic

cannot be read)

-

0x000E

Reserved

(PROFIdrive profile V2: Name in the cyclic traffic

cannot be read)

-

0x000F

No text array available

Access to unavailable text array (parameter value is

available)

-

0x0010

Reserved

(PROFIdrive profile V2: PPO-Write is missing)

-

0x0011

Job cannot be executed due

to operating status

Access is not possible for temporary reasons that are

not specified in detail

-

0x0012

Reserved

(PROFIdrive-Profil V2: Other error)

-

0x0013

Reserved

(PROFIdrive profile V2: date in the cyclic traffic

cannot be read)

-

0x0014

Impermissible value

Change access with a value that is within the value

limits but is not permissible for other permanent

reasons (parameter with defined single values)

Subindex

0x0015

Response is too long

The length of the current response exceeds the

maximally transferrable length

-

0x0016

Impermissible parameter

address

Impermissible value or value which is not supported

for the attribute, number of subindexes, parameter

number, or subindex, or a combination

-

0x0017

Impermissible format

Write request: Impermissible parameter data format

or parameter data format which is not supported

-

0x0018

Number of values are not

consistent

Write request: Number of parameter data values

does not match the number of subindexes in the

parameter address

-

Advertising