Communication manual 8400 motec PROFINET

Commissioning

Setting the IP configuration

6.4.1

Settings via the PROFINET configurator of the »Engineer«

How to set the IP parameters via the PROFINET configurator:

1. Execute the menu command Online Profinet configurator addresses....

The Assign IP addresses dialog window is opened, and all Lenze PROFINET devices

connected are listed.

Note!

• The IP address must only be allocated manually in the »Engineer« if the

PROFINET network is not actuated on the IO controller yet (IP address was not

allocated by the IO controller yet).

• During the IP parameters are set in the »Engineer«, PROFINET communication

with the IO controller must not take place at the same time.

• Changes will be effective immediately and are saved with mains failure

protection.