3 external voltage supply, External voltage supply – Lenze E84DGFCR User Manual

Page 25

Advertising
background image

EDS84DMOTPNET EN 2.0 - 11/2011

L

25

Communication manual 8400 motec PROFINET

Installation

Electrical installation

5.2.3

External voltage supply

 The external voltage supply can be used to establish PROFINET communication for

commissioning and to query the data of the digital and analog inputs.

 Furthermore the external voltage supply serves to maintain PROFINET communication

if the main supply fails.

 The digital inputs RFR, DI1 ... DI5 and the analog input can continue to be evaluated.
 The external voltage supply is done via the terminals 24E and GND of the terminal strip

X3.

 Permissible voltage (DC) / max. current:

– U = 24 V DC (20 V - 0 % ... 29 V + 0 %)
– I

max

= 400 mA

 Access to parameters of a device that is disconnected from the mains is not possible.

"Inverter Drives 8400 motec" hardware manual
Here you can find detailed information on how to wire the Communication Unit.