2 response after a read error, Response after a read error, Communication manual 8400 motec profinet – Lenze E84DGFCR User Manual

Page 50

Advertising
background image

Communication manual 8400 motec PROFINET

Parameter data transfer

Reading parameters from the controller

50

L

EDS84DMOTPNET EN 2.0 - 11/2011

Parameter value

9.2.2

Response after a read error

Response head

Parameter format

Byte 7

Byte 8

Byte 9

Byte 10

Value

Field

Data type

Values

Value

String

Any

U8

0x00 .... 0xFF

U16

0x0000 .... 0xFFFF

U32

0x0000 0000 .... 0xFFFF FFFF

Byte 1

Byte 2

Byte 3

Byte 4

Request reference

(mirrored)

Response identification

Axis

(mirrored)

Number of indices

Field

Data type

Values

Request reference

U8

Mirrored value of the parameter request

Response identification

U8

0x81: Parameters not read

• The data in bytes 7 + 8 are to be interpreted as error

code.

Axis

U8

0x00 or 0x01

Number of indices

U8

0x"n" (n = number of parameters requested)

Byte 5

Byte 6

Format

Number of values

Field

Data type

Values

Format

U8

0x44: Error

Number of values

U8

0x01: Error code without additional information

0x02: Error code with additional information