Communication manual 8400 motec PROFINET

Process data transfer

Process input data AI/DI (Slot2)

44

L

EDS84DMOTPNET EN 2.0 - 11/2011

8.3

Process input data AI/DI (Slot2)

 0, 1, or 2 input words can be optionally assigned to slot 2.
 The data represent the states of the digital inputs (RFR, DI1 ... DI5) and the analog input

of the device.

 Via the fieldbus these data can even be read when no mains voltage is applied to the

Communication Unit and only the fieldbus interface connection is supplied with

24 V DC.

Data word

Bits

Function

Value / description

Word 1

0

...

9

Analog input value

(0 ... 10 V)

10 V = 1000

10

Digital input 3

0 (FALSE)

Open

1 (TRUE)

Closed

11

Digital input 4

0 (FALSE)

Open

1 (TRUE)

Closed

12

Digital input 5

0 (FALSE)

Open

1 (TRUE)

Closed

13

Reserved

14

I/O status

0 (FALSE)

Data in word 1/2 are not valid.

1 (TRUE)

Data in word 1/2 are valid.

15

Connection status of the

controller

0 (FALSE)

Controller is offline ("Stay alive" operation)

1 (TRUE)

Controller is online

Word 2

0

RFR

0 (FALSE)

Open

1 (TRUE)

Closed

1

Digital input 1

0 (FALSE)

Open

1 (TRUE)

Closed

2

Digital input 2

0 (FALSE)

Open

1 (TRUE)

Closed

3

Digital input 3

0 (FALSE)

Open

1 (TRUE)

Closed

4

Digital input 4

0 (FALSE)

Open

1 (TRUE)

Closed

5

Digital input 5

0 (FALSE)

Open

1 (TRUE)

Closed

6

...

13

Reserved

14

I/O status

0 (FALSE)

Data in word 1/2 are not valid.

1 (TRUE)

Data in word 1/2 are valid.

15

Connection status of the

controller

0 (FALSE)

Controller is offline ("Stay alive" operation)

1 (TRUE)

Controller is online