13 parameter reference, C01501 | resp. to communication error with mci, C01503 | mci timeout – Lenze E84DGFCR User Manual

Page 73: Parameter reference, Be set via code, C01501, C01501/2, Communication manual 8400 motec profinet

Advertising
background image

EDS84DMOTPNET EN 2.0 - 11/2011

L

73

Communication manual 8400 motec PROFINET

Parameter reference

Communication-relevant parameters of the operating system

13

Parameter reference

This chapter complements the parameter list and the table of attributes in the software

manual and the »Engineer« online help for the Inverter Drive 8400 motec by the

parameters for PROFINET communication.

13.1

Communication-relevant parameters of the operating system

This chapter lists the communication-relevant parameters of the 8400 motec operating

system in numerically ascending order.

C01501

C01503

Software manual/»Engineer« online help for the "Inverter Drive 8400 motec"
Here you will find general information about parameters.

Parameter | Name:

C01501 | Resp. to communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring functions for the Communication Unit
Selection list

0 No response
1 Error
4 Warning locked

Subcodes

Lenze setting

Info

C01501/1

1: Error

Resp. to MCI error 1

• Response to a communication error.

C01501/2

1: Error

Resp. to MCI error 2

• Response to a fault in the Communication Unit.

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Scaling factor: 1

Parameter | Name:

C01503 | MCI timeout

Data type: UNSIGNED_16

Index: 23072

d

= 5A20

h

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C01503/1

200 ms

MCI timeout

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Scaling factor: 1

Advertising