Communication manual 8400 motec profinet – Lenze E84DGFCR User Manual
Page 58
Advertising
![background image](/manuals/565825/58/background.png)
Communication manual 8400 motec PROFINET
Parameter data transfer
Writing parameters to the controller
58
L
EDS84DMOTPNET EN 2.0 - 11/2011
Parameter response after a correct write request
Parameter response after write error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x02
0x00
0x01
(mirrored)
Parameters written
(mirrored)
1 index
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x82
0x00
0x01
(mirrored)
Parameters not written
(mirrored)
1 index
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Error
Error code without additional
information
Byte 7
Byte 8
Error code
High byte
Low byte
For meaning see chapter "