C13011 | active subnetwork mask, C13012 | active gateway address, C13850 | all words to master – Lenze E84DGFCR User Manual

Page 76: C13011, C13012, Communication manual 8400 motec profinet

Advertising
background image

Communication manual 8400 motec PROFINET

Parameter reference

Parameters relevant for PROFINET communication

76

L

EDS84DMOTPNET EN 2.0 - 11/2011

C13011

C13012

C13850

Parameter | Name:

C13011 | Active subnetwork mask

Data type: UNSIGNED_8

Index: 11564

d

= 2D2C

h

Display of the active subnetwork mask

• The active subnetwork mask may differ from the contents of code

C13001

, depending on whether the station

name was changed via the fieldbus or the parameter.

Display area

(min. value | unit | max. value)

0

255

Subcodes

Info

C13011/1

Active subnetwork mask.1

C13011/2

Active subnetwork mask.2

C13011/3

Active subnetwork mask.3

C13011/4

Active subnetwork mask.4

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13012 | Active gateway address

Data type: UNSIGNED_8

Index: 11563

d

= 2D2B

h

Display of the active gateway address

• The active gateway address may differ from the contents of code

C13002

, depending on whether the station

name was changed via the fieldbus or the parameter.

Display area

(min. value | unit | max. value)

0

255

Subcodes

Info

C13012/1

Active gateway address.1

C13012/2

Active gateway address.2

C13012/3

Active gateway address.3

C13012/4

Active gateway address.4

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13850 | All words to master

Data type: UNSIGNED_16

Index: 10725

d

= 29E5

h

Display of the process data words which are transmitted from the controller to the IO controller.

In the subcodes 1 to 8, all process data words to the I/O controller are displayed. However, only the configured

process data words are valid.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13850/1
...
C13850/8

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Advertising