Communication manual 8400 motec PROFINET

Parameter reference

Parameters relevant for PROFINET communication

C13851

C13860

Parameter | Name:

C13851 | All words from master

Data type: UNSIGNED_16

Index: 10724

d

= 29E4

h

Display of the process data words which are transmitted from the IO controller to the controller.

In the subcodes 1 to 8, all process data words from the I/O controller are displayed. However, only the configured

process data words are valid.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13851/1
...
C13851/8

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13860 | Settings

Data type: UNSIGNED_8

Index: 10715

d

= 29DB

h

Display area

(min. value | unit | max. value)

0

255

Subcodes

Info

C13860/1

Reserved

C13860/2

Number of process data words

C13860/3

Reserved

C13860/4

Reserved

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT