37
Communication manual 8400 motec PROFINET
Commissioning
Initial switch-on
6.6
Initial switch-on
Establishing communication
To establish communication, the controller must be supplied with mains voltage.
The external voltage supply serves to keep up PROFINET communication in the event of
a main supply failure.
During mains connection, all parameters (codes) are read.
If an error occurs, the error message "CE04: MCI communication error" (error no.
01.0127.00002) is output.
Addressing can be effected automatically via the IO controller or manually via codes in
the »Engineer«.
For addressing the controller, a valid IP configuration is required if communication
between the PC/»Engineer« and the controller is to be effected via PROFINET.