C13901 | firmware compilation date, C13902 | firmware version, C13910 | i&m1 system designation – Lenze E84DGFCR User Manual

Page 83: C13911 | i&m1 installation site, C13912 | i&m2 installation date, C13913 | i&m3 additional information, C13910, C13911, C13912, C13913

Advertising
background image

EDS84DMOTPNET EN 2.0 - 11/2011

L

83

Communication manual 8400 motec PROFINET

Parameter reference

Parameters relevant for PROFINET communication

C13901

C13902

C13910

C13911

C13912

C13913

Parameter | Name:

C13901 | Firmware compilation date

Data type: VISIBLE_STRING

Index: 10674

d

= 29B2

h

The code contains a string with a length of 20 characters. The software creation date ("MMM DD YYYY") and time

("hh:mm:ss") are displayed (e.g. "Mar 21 2005 12:31:21").

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13902 | Firmware version

Data type: VISIBLE_STRING

Index: 10673

d

= 29B1

h

The code contains a string with a length of 11 characters. The identification code is displayed (e.g. "01.00.00.00").

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13910 | I&M1 System designation

Data type: VISIBLE_STRING

Index: 10665

d

= 29A9

h

Input/output of the I&M1 plant identification code

• The Lenze setting shows an empty string.

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13911 | I&M1 Installation site

Data type: VISIBLE_STRING

Index: 10664

d

= 29A8

h

Input/output of the I&M1 location identification code

• The Lenze setting shows an empty string.

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13912 | I&M2 Installation date

Data type: VISIBLE_STRING

Index: 10663

d

= 29A7

h

Input/output of the I&M2 date of installation

• The Lenze setting shows an empty string.

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13913 | I&M3 additional information

Data type: VISIBLE_STRING

Index: 10662

d

= 29A6

h

Input/output if the I&M3 additional information

• The Lenze setting shows an empty string.
Subcodes

Lenze setting

Info

C13913/1

I&M3 additional information

C13913/2

I&M3 additional information

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Advertising