3 diagnostic data, Diagnostic data, Communication manual 8400 motec profinet – Lenze E84DGFCR User Manual

Page 67

Advertising
background image

EDS84DMOTPNET EN 2.0 - 11/2011

L

67

Communication manual 8400 motec PROFINET

Diagnostics

Diagnostic data

11.3

Diagnostic data

 The I/O device sends an alarm message to the I/O controller to signalise the diagnostic

data below.

 Errors and warnings in the Inverter Drive 8400 motec are sent to the IO controller as

extended diagnostic messages.

 The diagnostic data can be displayed using the hexadecimal representation of the

Siemens S7 engineering tool.

Error code of the Inverter Drive 8400 motec

 Bytes 29 ... 32 of the diagnostic message contain the error code.
 In the logbook and in code C00165, the error number is shown in the following syntax

in order to facilitate the readability:
[error type].[error subject area no.].[error ID]

Example: error message "

PROFINET: Data_Exchange status quit [0x01bc6531]

"

Bytes

Meaning

Value [hex]

1 ... 6

Diag. block header

0x0010 001C 0100

7 ... 8

Alarm type

0x0001 (diagnosis)

9 ... 12

API

0x0000 0000

13, 14

Slot number

0x0001 / 0x0002

15, 16

Subslot number

0x0001

17 ... 20

Module ID

ID according to module

21 ... 24

Submodule ID

ID according to module

25, 26

Alarm specifier

0xB000

27, 28

User structure identifier

0x0001

29 ... 32

Error code of the Inverter Drive 8400 motec

Byte 32

Byte 31

Byte 30

Byte 29

0x01

0xbc

0x65

0x31

0

0 0 0 0 0 0 1 1 0 1 1 1 1 0 0 0 1 1 0 0 1 0 1 0 0 1 1 0 0 0 1

Reaction

Instance ID

Module ID

Error ID

Software manual/»Engineer« online help for the "Inverter Drive 8400 motec"
Detailed information on the error codes is provided here.

Byte 32

Byte 31

Byte 30

Byte 29

Bit

16

25

26

31

0

15

29

30

Advertising