C13877 | bus error(1), C13878 | bus error(2), Communication manual 8400 motec profinet – Lenze E84DGFCR User Manual

Page 80

Advertising
background image

Communication manual 8400 motec PROFINET

Parameter reference

Parameters relevant for PROFINET communication

80

L

EDS84DMOTPNET EN 2.0 - 11/2011

C13877

C13878

Parameter | Name:

C13877 | Bus error(1)

Data type: UNSIGNED_16

Index: 10698

d

= 29CA

h

The code contains the error currently detected on the fieldbus.

• The error values can occur in combination with the error values from code

C13878

.

Selection list

(read only)

Info

0 No fail
1 Internal error
2 Unit ID unknown
3 Max. units exceeded
4 Invalid size
5 Unit type unknown
6 Runtime plug
7 Invalid argument
8 Service pending
9 Stack not ready

10 Command unknown
11 Invalid address descriptor
12 Watchdog expired
13 Protocol not supported

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13878 | Bus error(2)

Data type: BITFIELD_16

Index: 10697

d

= 29C9

h

The code contains the error currently detected on the fieldbus.

• The error values can occur in combination with the error values from code

C13877

.

Value is bit-coded:

Info

Bit 0 Reserved

... ...

Bit 6 Reserved
Bit 7 IP address error
Bit 8 Station name error
Bit 9 DataExch left

Bit 10 Stack boot error
Bit 11 Stack online error
Bit 12 Stack state error
Bit 13 Stack revision error
Bit 14 Stack init error
Bit 15 Stack CPU boot error

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT