8display functions, 1 code set, 2 language – Lenze 8615E User Manual

Page 101

Advertising
background image

99

8

Display functions

8.1

Code set

All codes in the inverter are arranged in different code sets. With
factory setting, the standard code set is activated. It contains all
codes which are required for the most common applications.

By selecting the extended code set under code C000, the display of
the keypad also shows those codes which are suitable for special
applications.

There is also a service code set which is not accessible in general.

Password
If you want to protect your parameter settings from non-authorized
access you can enter a password in the form of a three-digit
number. By defining a password, the parameters of the standard
code set can only be read, but not changed when the password is
not entered. The parameters of the extended code set can neither
be read nor changed.

First enter the password under C094 and then set code C000 to
"standard code set read only". After this, the setting of code C000
can only be changed when the programmed password is entered.

Code

Parameter

Meaning

Acceptance

C000

-0-
-1-
-2-
-9-

Standard code set read only
Standard code set
extended code set
Service code set

SH + PRG

C094*

xxx

Password

SH + PRG

*

extended code set

8.2

Language

Under code C098 you can select the language of the display texts.
The standard setting is German.

Code

Parameter

Meaning

Acceptance

C098

-0-
-1-
-2-

German
˝English
French

SH + PRG

Advertising
This manual is related to the following products: