Lenze 8615E User Manual

Page 19

Advertising
background image

17

3.2

Applications with high overload,
peak torque up to 170% of the rated motor torque

−

For applications which require a standard
overload behaviour of an inverter (e.g. general
mechanical engineering, hoists, travelling drives,
calenders).

−

The inverter provides 150% of the rated torque for
a maximum of 30s.
In the event of cyclic overload, the ratio of overload

time and cycle time must not exceed 0.1.

−

For this application, the monitoring of the output

current is set to operation with increased power

using the codes C119 and C120 (see page 97).

−

Please note that a maximum ambient temperature
of 45°C is permissible.

Type

Order no.

Rated

motor

power

kW

Rated

output

current

A

max.

output

current

A for 30s

Output power

kVA

400V 50Hz 480V 60Hz

Mains

current

A

Power

loss

W

8601

33.8601_E

1.5

4.0

6.0

2.77

3.33

4.0

140

8602

33.8602_E

2.2

5.3

7.8

3.67

4.41

5.3

155

8603

33.8603_E

3.0

7.4

11.0

5.13

6.15

7.4

180

8604

33.8604_E

4.0

10.1

15.0

7.0

8.4

9.4

210

8605

33.8605_E

5.5

12.7

19.0

8.8

10.6

11.8

235

8606

33.8606_E

7.5

17.6

26.0

12.2

14.6

16.3

290

8607

33.8607_E

11.0

22.7

33.0

15.7

18.9

20.7

340

8608

33.8608_E

15.0

31.7

47.0

22.0

26.3

28.0

440

8609

33.8609_E

18.5

43.2

64.0

29.9

35.9

38.0

560

8610

33.8610_E

22.0

53.3

79.0

36.9

44.3

47.0

670

8611

33.8611_E

30.0

63.5

94.0

44.0

52.8

55.0

775

8612

33.8612_E

37.0

81.0

120.0

56.1

67.3

71.0

960

8613

33.8613_E

45.0

101.0

150.0

70.0

84.0

84.0

1175

8614

33.8614_E

55.0

120.0

178.0

83.1

99.8

105.0

1375

8615

33.8615_E

75.0

148.0

220.0

103.0

123.0

129.0

1675