1 tightening torques of the power terminals, 2 control connections – Lenze 8615E User Manual

Page 29

Advertising
background image

27

5.1.1 Tightening torques of the power terminals

Type

8601...8605

8606, 8607

8608...8611

8612, 8613

8614, 8615

Tightening
torque

0.6...0.8 Nm
(5.3...7.1 lbfin)

1.2...1.5 Nm
(10.6...13.3 lbfin)

1.5...1.8 Nm
(13.3...16 lbfin)

6...8 Nm
(53...70 lbfin)

15...20 Nm
(133...177 lbfin)

5.2

Control connections

Layout:

X1

X2

X3

X4

X5

X6

X8

X9

V1

V2

E7 E8 39 40 41

44 45

K11 K14 A1

A2 A3 A4 59

60 62 63 VE9 GND FE

1

2

3

4

7

8

9

10 11

12

20

21 22

28

E1 E2 E3 E4 E5 E6

1

5

6

9

5

1

9

6

X11

1

8

9

15

X10

8

1

15

9

1

5

6

9

5

1

9

6

X1 to X4:

Control terminals

X5:

Input of digital frequency/incremental encoder

X6:

LECOM interface (RS232/485)

X8:

2nd input of digital frequency/incremental encoder
(option)

X9:

Output of digital frequency (option)

X10, X11:

Field bus connections
(Option, e.g. 2110IB for InterBus-S)

V1, V2;

Displays for field bus options

Note

Always connect the plug-in terminals (accessory kit) to the plug
connectors X1 to X4.
When not using the interface plugs (plug-in connectors) X5 and X6
protect them with the supplied covers.

It is possible to change the functions of certain control terminals
using switches (see chapters 5.2.1 to 5.2.7, page 28ff ). To adjust
the switches, remove the cover of the device.

In addition to this, there are numerous possibilities to change the
inputs and outputs of the device using codes (see page 78ff).