2warning, 3monitoring – Lenze 8615E User Manual

Page 121

Advertising
background image

119

2

Warning

A warning is displayed automatically under C067. During a warning
the signal "ready" is removed, however, the operation of the
frequency inverter is not interrupted.

Reset of the warning:

Press SH + PRG
or
activate the input TRIP reset.

List of warnings

Display on
keypad

Display on
host

Fault

Cause

Remedy

W51

203

Overheat PTC
input

Motor is overheated
PTC connecting cable
interrupted

PTC input open

Check dimensioning of the drive
Check PTC connection

W91

241

External fault

Signal via digital input "fault
indication"
Incorrect programming of the
input "fault indication"

Check external feedback source

Check programming of the input
"fault indication"

3

Monitoring

A monitoring indication causes a pulse inhibit and is displayed on
the keypad.The keys are out of order. Pulse inhibit is automatically
reset when the DC bus voltage has reached again its permissible
vlaue.

List of monitoring indications

Display on
keypad

Fault

Cause

Remedy

LU

Low voltage

Mains voltage is too low

Check mains voltage

OU

Overvoltage

Mains voltage is too high

˝

Creeping earth fault on the motor
side

Check mains voltage
Increase deceleration times,
when using a brake chopper,
check dimensioning and
connection of the brake resistor,
increase deceleration times
Check motor cable and motor for
earth fault (disconnect motor and
inverter)

Advertising