5.2.5 Digital inputs and outputs

The functions for the digital inputs and outputs shown below are
factory-set. To switch the signal cables, only use relays with low-
current contacts. Relays with gold-plated contacts have proven for
this.

All digital inputs and outputs are PLC compatible and are - when
operated with an external voltage supply (24 V) - isolated from the
rest of the control stage. To connect the voltage supply, use
terminals 39 and 59. If there is no external voltage supply, the
internal 15 V-supply can be used.

External voltage supply (24 V)

Inputs:
Input voltage:

0 to 30 V
LOW signal:

0 to 5 V

HIGH signal:

13 to 30 V

Input current:

for 24 V 8 mA per input

Outputs:
Maximum voltage supply:

30 V

Maximum output current:

50 mA per output (external
resistor at least 480

for 24 V,

e.g. relay, part no. 326 005)

A3

45

40

22

X2

X4

20 21

28 E1 E2 E3 E4 E5 E6

E7 E8

41 44

A1

A2

A4 59

_

X3

39

22k

10R

2.

7k

10k

+

15V 1

00m

A

R

L

GND

GND ext.

+

QSP

Ctrl.
enable

DC brake

JOG

Ti

TRIP-
set/reset

TRIP

RDY

IMP

Qmin

Imax

RFG/O=I

S2

3k

3k

3k

3k

3k

3k

3k

3k

3k

3k

50

m

A

50

m

A

50

m

A

50

m

A

50

m

A

50

m

A

50

m

A

6 x f

d