Attribute table

If you want to write programs yourself, the following table gives you
information for the serial communication via LECOM1 (LECOM-
A/B) or LECOM2.

Legend

Code

Meaning

Code

Lenze code number

DS

Data structure
E =

Single variable (only one parameter element)

A =

Array variable (several parameter elements can be selected by the code for the
preselection or by LECOM sub code).

I =

Image variable (several parameter elements can only be selected by the code for
the preselection)

P/S

Parameter setting/Control (Combination according to C001)
P =

Parameter setting

S =

Control

DT

Data type
B8 =

1 Byte bit coded

B16 =

2 Byte bit coded

VS =

ASCII String

FIX32 = 32-bit value with sign; decimal with four decimal places

Examples:
1.2 = 12000

FIX32-dez

00002EEO

FIX32-hex

-10.45 = -104500

FIX32-dez

FFFE67CC

FIX32-hex

N16 = 16-bit value with sign; 0 = 0; 100% = 2

14

100% = 16384

N16-dez

4000

N16-hex

-50% = -8192

N16-dez

E000

N16-hex

DL

Data length in byte

LCM-R/W

Access authorization for LECOM
Ra

= Reading is always permitted

W

= Writing permitted under certain conditions (e.g. operating mode, controller inhibit)

Wa

= Writing is always permitted

LCM1-Form.

LECOM A/B format (see technical description LECOM A/B)

AIF-PZD

High resolution data in automation interface.
Mapping on LECOM2 high resolution channel is possible.
PZD =

High resolution data

LCM2-Index

Number (Index) under which the parameter is addressed when using LECOM 2.