10.3.9 High resolution data

Under codes C380 to C382 you can enter very precise set-value
and feedback with a resolution of 14 bit plus sign.

Set-value 1:
Set-value scaled to the maximum frequency. The value of 2

14

corresponds to 100% of the maximum field frequency. The
information is identical with that under C046, with the difference
that you can read the controller value directly thus excluding
conversion errors.

Total set-value:
Total of main set-value 1 and set-value 2, each behind the ramp
generator, scaled to the maximum field frequency. The total set-
value corresponds to the set-value of the PI controller in closed-
loop control. The value of 2

14

corresponds to 100% of the

maximum field frequency.

Feedback of PI controller
Feedback for the PI controller, scaled to the maximum field
frequency. The value of 2

14

corresponds to 100% of the maximum

field frequency. The information is identical with that under C051,
with the difference that you can read the controller value directly
thus excluding conversion errors.

Code

Parameter

Meaning

Acceptance

C380

-16384 to +16384

Set-value 1

C381

-16384 to +16384

Total set-value

only display

C382

-16384 to +16384

Feedback of PI controller

only display