Code

Name

Parameter
(Factory settings are printed in bold)

Acceptance see

page

Your
settings

C108

Gain for C110 1.00

-10.00...+10.00
(in steps of 0.01)

ON-LINE

89

C109

Offset for
C110

0mV

-1000...+1000mV
(in steps of 1mV)

ON-LINE

89

C110

Preselection:
monitor output

-1-

Analog output terminal 62

-2-

Analog output terminal 63

SH + PRG

89

C111

Monitor signal
for C110

-0-

No signal

-2-

Ramp generator input
(Set-value 1, JOG frequency)

-5-

Total set-value (total from main
set-value and set-value 2)

-6-

Feedback of PI controller

-7-

Output of PI controller

-9-

Output frequency

-23-

Motor current

-30-

Motor voltage

-31-

DC bus voltage

SH + PRG

89

C112

Preselection:
freely
assignable
digital input

-1-

digital input E1

-2-

digital input E2

...

...

-8-

digital input E8

SH + PRG

78,
79

C113

Function for
C112

-0-

No function

-1-

Enable additional pair of ramp times

-2-

Enable JOG frequencies

-3-

Reset TRIP

-4-

Set TRIP

-5-

Activate DC injection braking

-7-

Integral action component = 0

-9-

Ramp generator stop

-10-

Ramp generator input = 0

-13-

Activate process control

-20-

Select parameter set

-21-

Load parameter set

[SH + PRG] 78,

79

C114

Polarity for
C113

-0-

Input HIGH active

-1-

Input LOW active

[SH + PRG] 78,

79

C115

Priority for
C113

-0-

Function can be changed via C001

-1-

Function can be activated via terminals
independently of C001

[SH + PRG] 78,

79

C116

Preselection:
freely
assignable
digital output

-1-

Digital output A1

-2-

Digital output A2

-3-

Digital output A3

-4-

Digital output A4

-5-

Relay output K11/K14

SH + PRG

86,
87

C117

Function for
C116

-0-

No function

-1-

Output frequency smaller than
Q

min

-threshold

-3-

Maximum current reached

-4-

Ready

-5-

Pulse inhibit

-6-

Fault indication

-9-

Set-value reached

-10-

Feedback = set-value

-11-

Feedback = 0

-14-

Flying restart circuit active

-30-

Process control active

-31-

Process step 1 active

-32-

Process step 2 active

-33-

Process step 3 active

-34-

Process step 4 active

-35-

Process step 5 active

-36-

Process step 6 active

-37-

Process step 7 active

-38-

Process step 8 active

SH + PRG

86,
87

C118

Polarity for
C117

-0-

Output HIGH active

-1-

Output LOW active

SH + PRG

86,
87

Advertising