6 rfi filters, 1 ratings of rfi filters – Lenze 8615E User Manual

Page 50

Advertising
background image

48

6.6

RFI filters

Advantage of using a RFI filter:

Reduction of high-frequent radio interference.

Please note:

Because of the generation of leakage currents, the RFI filters
must be connected to earth. The RFI filter must always be
connected to earth at first even if you only want to test the
system.
Otherwise, the system is not protected against shock.

The filters listed in the following can be connected to the 400 V
mains.
If you need filters for mains voltages of 460 V or 480 V, please
contact the factory.

6.6.1 Ratings of RFI filters

The ratings of the RFI filters depend on the mains current which is
permanently applied.

Operation at rated power (factory setting)

Inverter type

Rated filter current

Order number

8601...8603

8 A

EZF3-008A001

8604...8606

16 A

EZF3-016A001

8607...8608

25 A

EZF3-025A001

8609...8610

36 A

EZF3-036A001

8611

50 A

EZF3-050A004

8612...8613

80 A

EZF3-080A001

8614

110 A

EZF3-110A001

8615

180 A

EZF3-180A001

Operation at increased power

Inverter type

Rated filter current

Order number

8601...8603

8 A

EZF3-008A00

8604...8606

16 A

EZF3-016A001

8607

25 A

EZF3-025A001

8608

36 A

EZF3-036A001

8609...8610

50 A

EZF3-050A004

8611...8612

80 A

EZF3-080A001

8613...8614

110 A

EZF3-110A001

8615

180 A

EZF3-180A001

Operation at maximum power

Inverter type

Rated filter current

Order number

8601...8602

8 A

EZF3-008A001

8603...8604

16 A

EZF3-016A001

8606

25 A

EZF3-025A001

8608...8609

50 A

EZF3-050A004

8610

80 A

EZF3-080A001

8612

110 A

EZF3-110A001

8613...8614

180 A

EZF3-180A001

Advertising