2 configuration – Lenze 8615E User Manual

Page 62

Advertising
background image

60

3.2

Configuration

Using code C005 you can determine the internal control structure
and the use of the set-value and feedback inputs. The following
configurations are possible:

Open-loop speed control:

Code

Parameter Meaning

Acceptance

Set-value 1

Set-value 2

Actual value

C005

-0-

Terminals 7/8, unipolar or
LECOM (bipolar) or
keypad (bipolar)

not active

not active

[SH + PRG]

-1-

Terminals 7/8(bipolar) or
LECOM (bipolar) or
keypad (bipolar)

Terminals 1/2
(bipolar)

not active

-2-

Input X5
Digital frequency (2-track)

Terminals 1/2
(bipolar)

not active

Closed-loop control:

Code

Parameter Meaning

Acceptance

Set-value 1

Set-value 2

Actual value

C005

-11-

Terminals 7/8 (bipolar) or
LECOM (bipolar) or
keypad (bipolar)

Terminals 1/2
(bipolar)

Terminals 3/4 analog
feedback (e.g. DC
tacho)

[SH + PRG]

-13-

Terminals 7/8 (bipolar) or
LECOM (bipolar) or
keypad (bipolar)

Terminals 1/2
(bipolar)

Input X5
Digital frequency (2-
track)

-14-*

Input X8
Digital frequency

Terminals 1/2
(bipolar)

Input X5
Digital frequency (2-
track)

-15-*

Input X5
Digital frequency (2-track)

Terminals 1/2
(bipolar)

Input X8
Pulse encoder (2-track)

* According to the configuration selected, set-value 1 or the feedback can

be output via the digital frequency output X9.

Advertising