7

Planning

1

Features of the 8600 inverter series

Liability

The information given in these Operating Instructions describe
the features of the products but do not guarantee them.

Power stage

Large mains voltage range: 3 x 330 to 528V AC or
470 to 740V DC

Inverter with IGBTs, protected against short circuits

4kHz chopper frequency, adjustable up to 16kHz

Output frequency up to 480Hz,
V/f rated frequency up to 960Hz

Overload capacity up to 200% rated current for a short time

Overload monitoring can be set

Integrated brake transistor, external brake resistors in IP20
enclosure as option

Connections for DC bus supply

Control stage

Digital control unit with 16-bit microprocessor

Simple parameter setting and diagnosis using keypad and two-
line display in German, English, and French language

Parameter setting during operation

V/f-characteristic control with linear or square characteristic

High breakaway torque by magnetizing current control

Constant speed due to slip compensation

Speed control using DC tacho or incremental encoder

Current limitation with V/f lowering for stall-protected operation

Motor overload monitoring via PTC input or

I

²

t-monitoring

Process control with a maximum of eight steps

Synchronisation coasting motor due to flying restart circuit

Serial interface (RS232C/RS485) for external parameter setting
and operation

Field bus connecting modules as option to be integrated into the
device

Approvals (unit types 8602 to 8611)

VDE 0160, VDE reg.-no. 86694

UL 508, file no. 132659

Advertising