5.4.9 Flying restart circuit active

If you have activated the flying restart circuit, the assigned output
indicates when the flying restart circuit is active. For further
information about the flying restart circuit see page 95.

5.4.10 Process control active, process step active

If you use the process control, the assigned outputs indicate when
the process control or individual steps are active. For further
information about the process control see page 94.

5.5

Monitor outputs

The inverter has two monitor outputs (terminals 62 and 63), to output
internal signals as voltage or current signals. The required switch
settings can be obtained from the table on page 29.

Factory setting:

Output

Function

Relationship

Terminal 62
Terminal 63

Output frequency
Motor current

10V corresponds to f

dmax

10V corresponds to 200% rated
inverter current

If you need another signal for an output, first select under C110,
which output you want to change. Under C111 you select the signal
which you want to assign to this output. To adapt the monitor
output, e.g. to a display instrument, you can adjust gain and offset
via C108 and C109.

Code

Parameter

Meaning/Function

Acceptance

C110

-1-
-2-

Monitor output1 terminal 62
Monitor output 2 terminal 63

SH + PRG

C111

-0-
-2-
-5-

-6-
-7-
-9-
-23-
-30-
-31-

No signal
Set-value 1 (10V corresponds to 100%)
Total set-value (total from main set-value and set-
value 2)
PI controller output (10V corresponds to 100%)
PI controller output (10V corresponds to 100%)
Output frequency (10V corresponds to f

dmax

)

Motor current (10V corresponds to 200% of max.
inverter current)

Motor voltage (10V corresponds to 1000V)
DC bus voltage (10V corresponds to 1000V)