5wiring, 1 power connections, Cable protection – Lenze 8615E User Manual
Page 28: Brake resistor, Mains contactor, Motor filter/motor supply filter, Mains choke, Terminal strip in the control cabinet
Advertising
26
5
Wiring
5.1
Power connections
K1
K1
R
B
L3
N
PE
L1
L2
L1
L2
L3
K1 K1 K1
1
2
3
;;
PE
BR1
BR2
4
5
6
7
OFF
ON
RB
ϑ
3~
PE
+U
G
-U
G
PE
PE
L1
L2
L3
L1
L2
L3
PE
+U
G
PE
U
V
W
U1
V1
W1
V
W
U
-U
G
1
Cable protection
5
Brake resistor
2
Mains contactor
6
Motor filter/Motor supply filter
3
Mains choke
7
Terminal strip in the control
cabinet
4
Mains filter
Screen connections at the
controller
All power terminals remain live up to 3 minutes after mains
disconnection!