3application-specific controller selection – Lenze 8615E User Manual

Page 18

Advertising
background image

16

3

Application-specific controller selection

3.1

Applications with extreme overload,
peak torque up to 230% of the rated motor torque

−

For applications where very extreme starting and

overload torques are necessary (e.g. presses, drilling

machines).

−

The inverter provides 200% of the rated torque for a
maximum of 30s.
In the event of cyclic overload, the ratio of overload

time and cycle time must not exceed 0.2.

−

For these applications, the monitoring of the output
current is set to operation with rated power
(factory setting) using the codes C119 and C120
(see page 97)

-

Please note that a maximum ambient temperature of
50°C is permissible.

1

1.5

1.2

1.8

2.3

n

n

N

V/f-control

M

M

N

I -control

0

Type

Order no.

Rated

motor

power

kW

Rated

output

current

A

max.

output

current

A for 30s

Output power

kVA

400V 50Hz 480V 60Hz

Mains

current

A

Power

loss

W

8601

33.8601_E

1.1

3.0

6.0

2.07

2.5

3.0

130

8602

33.8602_E

1.5

3.9

7.8

2.7

3.24

3.9

140

8603

33.8603_E

2.2

5.5

11.0

3.81

4.57

5.5

160

8604

33.8604_E

3.0

7.5

15.0

5.2

6.24

7.0

180

8605

33.8605_E

4.0

9.4

19.0

6.51

7.82

8.8

200

8606

33.8606_E

5.5

13.0

26.0

9.01

10.8

12.0

240

8607

33.8607_E

7.5

16.5

33.0

11.4

13.7

15.0

275

8608

33.8608_E

11.0

23.5

47.0

16.3

19.5

20.5

350

8609

33.8609_E

15.0

32.0

64.0

22.2

26.6

28.5

420

8610

33.8610_E

18.5

39.5

79.0

27.4

32.8

34.5

600

8611

33.8611_E

22.0

47.0

94.0

32.6

39.1

41.0

740

8612

33.8612_E

30.0

60.0

120.0

41.6

49.9

53.0

900

8613

33.8613_E

37.0

75.0

150.0

52.0

62.3

66.0

1050

8614

33.8614_E

45.0

89.0

178.0

61.7

74.0

78.0

1050

8615

33.8615_E

55.0

110.0

220.0

76.2

91.4

96.0

1270

Advertising
This manual is related to the following products: