3application-specific controller selection – Lenze 8615E User Manual

Page 18

Advertising
background image

16

3

Application-specific controller selection

3.1

Applications with extreme overload,
peak torque up to 230% of the rated motor torque

For applications where very extreme starting and

overload torques are necessary (e.g. presses, drilling

machines).

The inverter provides 200% of the rated torque for a
maximum of 30s.
In the event of cyclic overload, the ratio of overload

time and cycle time must not exceed 0.2.

For these applications, the monitoring of the output
current is set to operation with rated power
(factory setting) using the codes C119 and C120
(see page 97)

-

Please note that a maximum ambient temperature of
50°C is permissible.

1

1.5

1.2

1.8

2.3

n

n

N

V/f-control

M

M

N

I -control

0

Type

Order no.

Rated

motor

power

kW

Rated

output

current

A

max.

output

current

A for 30s

Output power

kVA

400V 50Hz 480V 60Hz

Mains

current

A

Power

loss

W

8601

33.8601_E

1.1

3.0

6.0

2.07

2.5

3.0

130

8602

33.8602_E

1.5

3.9

7.8

2.7

3.24

3.9

140

8603

33.8603_E

2.2

5.5

11.0

3.81

4.57

5.5

160

8604

33.8604_E

3.0

7.5

15.0

5.2

6.24

7.0

180

8605

33.8605_E

4.0

9.4

19.0

6.51

7.82

8.8

200

8606

33.8606_E

5.5

13.0

26.0

9.01

10.8

12.0

240

8607

33.8607_E

7.5

16.5

33.0

11.4

13.7

15.0

275

8608

33.8608_E

11.0

23.5

47.0

16.3

19.5

20.5

350

8609

33.8609_E

15.0

32.0

64.0

22.2

26.6

28.5

420

8610

33.8610_E

18.5

39.5

79.0

27.4

32.8

34.5

600

8611

33.8611_E

22.0

47.0

94.0

32.6

39.1

41.0

740

8612

33.8612_E

30.0

60.0

120.0

41.6

49.9

53.0

900

8613

33.8613_E

37.0

75.0

150.0

52.0

62.3

66.0

1050

8614

33.8614_E

45.0

89.0

178.0

61.7

74.0

78.0

1050

8615

33.8615_E

55.0

110.0

220.0

76.2

91.4

96.0

1270

Advertising
This manual is related to the following products: