Digital frequency output X9 (Option)

The connection of drives via digital frequency allows a simple and
precise control of multi-motor systems. The digital frequency output
X9 can be used here as digital frequency encoder, e.g. for parallel
or slave drives.

Assignment of socket X9

Pin

Name

Input/Output

Explanation

1
2
3
4
5
6
7
8
9

B
A\
A
---
GND
---
---
5V
B\

Output
˝Output
Output

Output
Output

2nd encoder signal
1st encoder signal inverse
1st encoder signal
Not used
Internal ground
Not used
Nt used
Lamp check
2nd encoder signal inverse

Depending on the relationship of the drive controlled via X9, you
can program under C008 if the input signals at X5 are to be output
unchanged or if an internal set-value signal is to be processed.
Internal set-value sources are:

Main set-value (Set-value 1/JOG frequency)

Ramp generator output (main set-value)

Total set-value (total of ramp generator outputs)

If you have selected an internal set-value signal as digital
frequency, you can also program its setting range under C030. The
frequency of the output signals results from

Output freq. = set-value signal

max. field freq. (C011)

constant (C030)

Please note that when processing the selected set-value signal
minor conversion errors may be possible.

Code

Parameter

Meaning

Acceptance

C008

-0-
-2-
-3-
-5-

Ouput of input signals at X5
Main set-value
Ramp generator output (main set-value)
Total set-value

SH + PRG

C030

-1-
-2-
-3-
-4-

512 pulses/Hz field frequency
1024 pulses/Hz field frequency
2048 pulses/Hz field frequency
4096 pulses/Hz field frequency

SH + PRG