Lenze 8615E User Manual

Page 104

Advertising
background image

102

Code

Name

Parameter
(Factory settings are printed in bold)

Acceptance see

page

Your
settings

C008

Output signal
digital
frequency

-0-

Output of input signals at X5

-2-

Main set-value (C046/JOG)

-3-

Ramp generator output
(main set-value)

-5-

Total set-value

SH + PRG

90

C009*

Controller
address (only
for LECOM)

1

1...99

SH + PRG

110

C010

Minimum field
frequency

0.0Hz

0.0...480Hz
(in steps of 0.1Hz from 0.0 to 100Hz
in steps of 1Hz from 100 to 480Hz)

ON-LINE

71

C011

Maximum field
frequency

50Hz

7.5...480Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 480Hz)

ON-LINE

71

C012

Acceleration
time
main set-value

5.0s

0.0...990s
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 990s)

ON-LINE

72

C013

Deceleration
time
main set-value

5.0s

0.0...990s
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 990s)

ON-LINE

72

C014

V/f
characteristic

-0-

linear characteristic V

f

d

-1-

square characteristic V

f

d

2

SH + PRG

68

C015

V/f rated
frequency

50Hz

7.5...960Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 960Hz)

ON-LINE

68,
70

C016

Voltage boost

0.0%

0... 40%
(in steps of 0.1%)

ON-LINE

69

C017

Threshold for
Q

min

function

2.0Hz

0.0...480Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 480Hz)

ON-LINE

87

C018

Chopping
frequency

-0-

1kHz (field frequency max. 120 Hz)

-1-

2kHz (field frequency max. 240 Hz)

-2-

4kHz variable

-3-

6kHz variable

-4-

8kHz variable

-5-

12kHz variable

-6-

16kHz variable

-7-

12kHz fixed (for motor supply filter)

-8-

16kHz fixed (for motor supply filter)

[SH + PRG] 91

C019

Threshold for
automatic DC
injection
braking

0.0Hz

0.0...480Hz
0.0Hz = automatic DC injection braking
switched off
(in steps of 0.1Hz from 0.0 to 100Hz
in steps of 1Hz from 100 to 480Hz)

ON-LINE

92

C020

I

0

set-value

Rated set-value (P

Nmotor

= P

Ncopntroller

)

0.0...0.5

I

maxcontroller

(in steps of 0.1 A from 0.0 to 100 A
in steps of 1 A as of 100 A)

ON-LINE

70

C021

Slip
compensation

0.0%

0.0...20 %
(in steps of 0.1%)

ON-LINE

92

C022

I

max

limit

I

maxcontroller

0.08...1.0

I

maxcontroller

(in steps of 0.1A to 100A
in steps of 1A ab 100A)

ON-LINE

87