4checking the power stage, 1 checking the mains rectifier, 2 checking the power stage – Lenze 8615E User Manual

Page 122

Advertising
background image

120

4

Checking the power stage

The measurements described below are to be carried out only by
skilled specialists. Use a digital voltmeter. The measuring values
indicate the nominal value. If they are different, there is a defective.

4.1

Checking the mains rectifier

Disconnect inverter from the mains and wait until the DC bus has
discharged (approx. 3 minutes). You can measure directly at the
power terminals.

Measurement

Measuring point

Measuring value

Diodes in forward
direction

L1

+UG

L2

+UG

L3

+UG

-UG

L1

-UG

L2

-UG

L3

0.4V

0.4V

0.4V

0.4V

0.4V

0.4V

Diodes in reverse
direction

+UG

L1

+UG

L2

+UG

L3

L1

-UG

L2

-UG

L3

-UG

high-resistance (OL)
high-resistance (OL)
high-resistance (OL)
high-resistance (OL)
high-resistance (OL)
high-resistance (OL)

4.2

Checking the power stage

Disconnect inverter from the mains and wait until the DC bus has
discharged (approx. 3 minutes).

You can measure directly at the power terminals.

Measurement

Measuring point

Measuring value

Inverter diode
in forward direction

U

+UG

V

+UG

W

+UG

0.4V

0.4V

0.4V

Diodes in reverse
direction

UG

U

UG

V

UG

W

high-resistance
high-resistance
high-resistance

Inverter diode in forward
direction

-UG

U

-UG

V

-UG

W

0.4V

0.4V

0.4V

Inverter diode
in reverse direction

U

-UG

V

-UG

W

-UG

high-resistance
high-resistance
high-resistance

4.3

Checking the voltage supply on the control
board 8602MP

Inhibit controller

Remarks

Measuring point

Measuring value

+Vcc 15

Term. 20

Term. 40

+14.25 V...+15.75 V

+Vref 10 V

Term. 9

Term. 40

+9.79 V...+10.21 V

-Vref 10 V

Kl. 10

Term. 40

-9.79 V... -10.21 V

Advertising
This manual is related to the following products: