Lenze 8615E User Manual

Page 85

Advertising
background image

83

Enabling the additional acceleration and deceleration times
With terminal control
activate the assigned digital inputs
according to the table below.

The input with the smallest number is the first input, the input with
the next highest number is the second input, etc.
(e.g. E7 = first input, E8 = second input).

1st input

2nd input

3rd input

4th input

T

ir

1, T

if

1

1

0

0

0

T

ir

2, T

if

2

0

1

0

0

T

ir

3, T

if

3

1

1

0

0

T

ir

4, T

if

4

0

0

1

0

T

ir

5, T

if

5

1

0

1

0

T

ir

6, T

if

6

0

1

1

0

T

ir

7, T

if

7

1

1

1

0

T

ir

8, T

if

8

0

0

0

1

T

ir

9, T

if

9

1

0

0

1

T

ir

10, T

if

10

0

1

0

1

T

ir

11, T

if

11

1

1

0

1

T

ir

12, T

if

12

0

0

1

1

T

ir

13, T

if

13

1

0

1

1

T

ir

14, T

if

14

0

1

1

1

T

ir

15, T

if

15

1

1

1

1

C130 displays the active pair of ramp times.

With control via keypad or LECOM interfaces C130 is used to
activate a pair of ramp times.

Code

Parameter

Meaning

Acceptance

C130

-0-
-1-
-2-
-...-
-15-

Activate standard pair of ramp times
Activate pair of ramp times 1
Activate pair of ramp times 2
Activate pair of ramp times ...
Activate pair of ramp times 15

SH + PRG

Advertising
This manual is related to the following products: