110

10.2

LECOM2 interface (option)

For more sophisticated applications, you can use a field bus
connecting interface. In the programming section, this interface is
called LECOM2. For the bus system Interbus-S the connecting
interface 2110 with the DRIVECOM profile is available. For the bus
system PROFIBUS the connecting module 2130 is also available
with DRIVECOM profile. The modules 2110 and 2130 are available
are options and can be integrated into the inverter (see also page
50).

10.3

LECOM codes

Some codes have a special meaning for the serial communication.
The codes C043, C068, C069, C161 to C168 cannot be read on the
dispaly of the device.

10.3.1 Controller address

Under code C009 you enter the bus participant number for the
communication via interface. The addresses 1 to 99 can be
assigned, but "10", "20", ... "90" are not possible.

10.3.2 Operating state

Under code C068, the operating state is displayed.

bit no.

15

14

13

12

11

10

9

8

Signal

TRIP

Feedback
= set-
value

Imax

Quick
stop

IMP

Dir. of
rotation

Qmin

Controller
enable

bit no.

7

6

5

4

3

2

1

0

Signal

Communication error

Operating fault

10.3.3 Controller state

Under code C069, the controller state is displayed.

bit no.

7

6

5

4

3

2

1

0

Signal

Ctrl.
enable

xxx

RESET

AUTO

REMOTE

PCHG

C-ALARM B-ALARM

10.3.4 Pole pair number

You must enter the pole pair number to calculate the speed.

Code

Parameter

Meaning

C092

1...6

Pole pair number