Code

Name

Parameter
(Factory settings are printed in bold)

Acceptance see

page

Your
settings

C086*

Motor frame
size

-0-

Size 71,

self-ventilated

-1-

Size 80,

self-ventilated

-2-

Size 90,

self-ventilated

-3-

Size 100,

self-ventilated

-4-

Size 112,

self-ventilated

-5-

Size 132,

self-ventilated

-6-

Size 160,

self-ventilated

-7-

Size 180,

self-ventilated

-8-

Size 200,

self-ventilated

-9-

Size 225,

self-ventilated

-10-

Size 250,

self-ventilated

-100-

Size 71,

forced-ventilated

-101-

Size 80,

forced-ventilated

-102-

Size 90,

forced-ventilated

-103-

Size 100,

forced-ventilated

-104-

Size 112,

forced-ventilated

-105-

Size 132,

forced-ventilated

-106-

Size 160,

forced-ventilated

-107-

Size 180,

forced-ventilated

-108-

Size 200,

forced-ventilated

-109-

Size 225,

forced-ventilated

-110-

Size 250,

forced-ventilated

[SH + PRG] 98

C088*

Rated motor
current

0.5

I

maxcontroller

0.15...1.0

I

maxcontroller

(in steps of 0.1A to 100A
in steps of 1A as of 100A)

[SH + PRG] 98

C092*

Pole pair
number (only
for LECOM)

2

1...6

[SH + PRG] 110

C094*

User password 000

000...999
000 = no password request
under C000

SH + PRG

99

C098

Language

-0-

German

-1-

English

-2-

French

SH + PRG

99

C099*

Software
version

-0-

86 6.4

100

C100

Preselection:
Additional
acceleration
and
deceleration
time (main set-
value)

-1-

Pair of ramp times 1

-2-

Pair of ramp times 2

...

...

-15-

Pair of ramp times 15

SH + PRG

81

C101

Acceleration
time for C100

2.5s

0.0...990 s
(in steps of 10 ms from 0.0 to 1 s
in steps of 100 ms from 1 to 10 s
in steps of 1 s from 10 to 100 s
in steps of 10 from 100 to 990 s)

ON-LINE

81

C103

Deceleration
time for C100

2.5s

0.0... 990 s
(in steps of 10 ms from 0.0 to 1 s
in steps of 100 ms from 1 to 10 s
in steps of 1 s from 10 to 100 s
in steps of 10 from 100 to 990 s)

ON-LINE

81

C105

Deceleration
time for quick
stop

5.0s

0.0...990 s
(in steps of 10 ms from 0.0 to 1 s
in steps of 100 ms from 1 to 10 s
in steps of 1 s from 10 to 100 s
in steps of 10 s from 100 to 990 s)

ON-LINE

58

C107

Holding time
for DC
injection
braking

999s

0.0...999s
999s = Holding time infinite
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 999s)

ON-LINE

79