Operation and Software

BA8230

111

RS422: Address

This parameter determines the unit address for the 8230 frequency inverter for
communication through the RS422 serial interface (with the PC).

Adjustment range:

0 ... 15

As supplied:

0

RS422: Baud rate

This parameter determines the transfer speed for serial communication through the
RS422 interface (PC).

Adjustment range:

2400 ... 19200 Baud

As supplied:

19200 Baud

Parameter set no.

This parameter indicates the currently active parameter set and allows switching to a
second parameter set through entry of a different numerical value. For this, Terminal:
Parameter Set Changeover
must be disabled.
Two parameter sets can be selected.

Range:

1, 2

As supplied:

1

Copy target: Set accessible on level 2

Function for copying all settings used in the currently active parameter set to another
parameter set selected with its parameter no. or by a terminal
signal (D-Input 3 terminal :16).
This parameter set is accessible on level 2.
To copy a parameter set the parameter copy target is to be set to 2 and then the
function: Copy: Parameter is executed. The value of the copy target parameter is to
be set to match the target parameter set number and is automatically reset to zero
after copying.