Lenze EDB9300UES User Manual
Page 62
![background image](/manuals/566237/62/background.png)
Technical Data
BA8230
57
Terminal :29/:30
ADDITIONAL DEMAND
Differential input, additional demand
As terminal :27/:28
Terminal :31
+ 10 V/ 20 mA
Supply voltage for
Terminal :32
- 10 V / 20 mA
Demand channels (short-circuit
resistant)
Terminal :31
DC +10 V 20 mA voltage supply for demand channels
Terminal :32
DC -10 V 20 mA voltage supply for demand channels
Terminal :33
A-OUTPUT 1
Analog output for an analog value 0 ... ±10 V
Function adjustable (04 Analog I/O
→
Terminal :33)
(Standard setting: Output frequency - see section 4.4.4)
Scaling adjustable through 04 Analog I/O - Scale analog output
Rating: 3 mA; load
≥
3.3 k
Ω
D/A transformer: 12 bit accuracy, 0.3 % resolution
Terminal :34
0 V Reference potential for DC ±10 V
Terminal :35
A-OUTPUT 2
Analog output for an analog value 0 ... ±10 V
As analog output 1
(Standard setting: Motor current - see section 4.4.4)
Terminal :36
DC 0V A-OUTPUT
0 V for analog outputs A-OUTPUT 1 and A-OUTPUT 2
}
Show/Hide Bookmarks