1.3 Main features

•

Consistent range of Types for drives from 110 kW to 250 kW with
IGBT inverters

•

Supply voltage ranges:

- 3AC 380 V ... 460 V +10 %/ -15 % ... 480 V +6 %/ -15 %

•

Standard design for connection to earthed networks

•

Output frequency range: 0 ... 300 Hz

•

120% overload capacity for 60 s related to 1.2 rated controller current
(Applications with medium overload)

•

150% overload capacity for 60 s related to 1.5 rated controller current
(Applications with high overload)

•

Standard asynchronous motors can be used without power reduction

•

High dynamics: Torque rise time: t

an

= 2 to 8 ms

•

8230 frequency inverter units are resistant to idling, short circuit and earth fault

•

DC system bus supply for several 8230 frequency inverter through
DC link connection (option)

•

4Q operation (option) through power dump with braking resistor

•

Mains supply power connections at top and motor connections at foot

•

Motor temperature monitoring by thermistor processing electronics (PTC)

•

Easy, user-friendly system structure

•

Consistent and easily learned operation via control unit (option) with plain
text display (various languages available)

•

Extensive additional operating facilities via PC, for example menu control,
user-controlled commissioning, oscilloscope function

•

Control structures available:
- Frequency control
- Speed control with or without incremental rotation encoder
- Torque control with or without incremental rotation encoder