5 parameters for digital i/o's, Parameters for digital i/o’s – Lenze EDB9300UES User Manual

Page 124

Advertising
background image

Operation and Software

BA8230

119

4.4.5 Parameters for digital I/O’s

D-Input 1 terminal 14

This parameter determines the function of the digital control input at terminal 14. The
function is active at logic “High”.

Select list:

- Motor potentiometer higher
- Select fixed speed1

As supplied:

Motor potentiometer higher

If the parameter is set to "Select fixed speed 1", one of the fixed speeds stated in
02 Application parameters according to the following table is activated in conjunction
with the function “Select fixed speed 2”:

Select fixed speed 1

Select fixed speed 2

Activated fixed speed

0

0

"Fixed speed 1"

1

0

"Fixed speed 2"

0

1

"Fixed speed 3"

1

1

"Fixed speed 4"

"Fixed speed 1" to "Fixed speed 4" are specified in 02 = APPLICATION
PARAMETERS.

IMPORTANT!

If the function of D-Input terminal :14 is not set to "Select fixed speed 1", the selection
matrix for Select fixed speed 1 is 0.

The activated fixed speeds are only effective if the parameter for the MANUAL
demand or AUTO demand in Menu 03 Configuration is set to fixed speed.

D-Input 2 terminal 15

This parameter determines the function of the digital control input at terminal :15. The
function is active at logic “High”.

Select list:

- Motor potentiometer lower
- Select fixed speed 2

As supplied:

Motor potentiometer lower

If the parameter is set to "Select fixed speed 2", one of the fixed speeds given in
02 Application parameters according to the following table is activated in conjunction
with the function “Select fixed speed 1”:

Show/Hide Bookmarks