Operation and Software
BA8230
127
Calibrate to 0
This parameter shows the value of the I
M
controller adjustment value and serves for
calibrating R-stator + R-cable of the motor used (see also the parameter “Calibration
mode”).
R-stator + R-cable
This parameter represents the line value of stator resistance for the asynchronous
motor connected plus the resistance of the supply cables. It serves as a model for the
replacement circuit diagram for preliminary control of the motor voltage and for
adapting the controller parameters.
The value is calculated from the motor type data entered and can be optimised if
required (see parameter “Calibration mode”).
Adjustment range:
0 Ohm ... 100 Ohm
As supplied:
Value from the parameter set for the standard
asynchronous motor suitable for the inverter type.
Fan Trigger
This parameter specifies the temperature threshold at which the fan(s) change(s) from
the low to high speed.
Adjustment range:
0 ... 65 °C
As supplied:
55 °C
The parameter can only be changed in protection level 2.